top of page

Item# P-10250

PROACTIVE ENVIRONMENTAL PRODUCTS®

12 Volt Tempest/Twister® Plastic Pump

(Lifts 60 Feet / 18 Meters DTW)

12 Volt Tempest/Twister Plastic Pump

The Engineered Plastic 12-volt submersible centrifugal Tempest/Twister® pump is capable of pumping up to 60 feet from ground level (DTW)* by simply connecting the Tempest/Twister® to a 12 volt deep cycle battery. Its reliable design is perfect for continuous sampling and purging of groundwater wells and Low Flow Sampling (Fractional Flow®).

 

The 12 Volt Tempest/Twister® is ideal for low flow sampling (Fractional Flow®) in conjunction with Proactive Environmental Products Low Flow Sampling Controller. Low flow sample all the way down to 40 mLs per minute. To achieve even a lower flow.... simply add the Low Flow Sampling Control Valve in conjunction with the Low Flow Sampling controller to achieve flow rates of 10 mLs per minute or less!

 

Simplify and Expedite Your Next Sampling Event!

  • The Tempest/Twister® can operate under harsh conditions with higher turbidity.

 

  • The Tempest/Twister® can run continuously in water without the need for a cool down!

 

  • The Tempest/Twister® has a 400 hour motor life!

 

  • The Tempest/Twister® has a sleek outside that minimizes well hang-ups.

 

  • The Tempest/Twister® is a very reliable and economical pump that provides a great bang for your buy!

 

This pump is not engineered to be dedicated in the physical liquid 24 hours a day.

* Depth to water

Specifications:

WATT CONSUMPTION (MAX):          165 WATTS (MAX)

DC VOLT RECOMMENDATION:          12-15 DC (direct current) At Source

AMP CONSUMPTION (MAX):            11 AMPS

MEASUREMENTS:                             LENGTH 17" / DIAMETER: 1.82"

REQUIRED TUBING:                          3/8" or 1/2" ID TUBING

SUPPLIED WITH:                              70 FEET OF HEAVY DUTY 12 GAUGE WIRE, QUICK 

                                                        DISCONNECT PLUG & BATTERY CLAMPS

PUMP CONSTRUCTION:                     ABS

IMPELLER CONSTRUCTION:               POLY ACETAL (POM)

MOTOR SHAFT CONSTRUCTION:        STAINLESS STEEL 

WIRE CONSTRUCTION:                      PVC

SEAL CONSTRUCTION:                       NITRILE 

  Pumping Depth in Feet              Gallons Per Minute    

   DTW (Depth To Water)        At 13.8 Volts At The Source

           

                   3                                           3.2

         

                 10                                           2.8

        

                 20                                           2.2

          

                 30                                           1.75

         

                 40                                           1.2

                 50                                           .75

                 55                                           .60

                 60                                           .40

                 70                                           N/A

 

Test was conducted with a Power Source at 13.8 volts.

 

Running your vehicle while using this pump

will dramatically increase purge volume

State Groundwater Monitoring Well Sampling Procedures:

  • Alabama Groundwater Monitoring Well Sampling Procedures

  • Alaska Groundwater Monitoring Well Sampling Procedures

  • Arizona Groundwater Monitoring Well Sampling Procedures

  • Arkansas Groundwater Monitoring Well Sampling Procedures

  • California Groundwater Monitoring Well Sampling Procedures

  • Colorado Groundwater Monitoring Well Sampling Procedures

  • Connecticut Groundwater Monitoring Well Sampling Procedures

  • Delaware Groundwater Monitoring Well Sampling Procedures

  • Florida Groundwater Monitoring Well Sampling Procedures

  • Georgia Groundwater Monitoring Well Sampling Procedures

  • Hawaii Groundwater Monitoring Well Sampling Procedures

  • Idaho Groundwater Monitoring Well Sampling Procedures

  • Illinois Groundwater Monitoring Well Sampling Procedures

  • Indiana Groundwater Monitoring Well Sampling Procedures

  • Iowa Groundwater Monitoring Well Sampling Procedures

  • Kansas Groundwater Monitoring Well Sampling Procedures

  • Kentucky Groundwater Monitoring Well Sampling Procedures

  • Louisiana Groundwater Monitoring Well Sampling Procedures

  • Maine Groundwater Monitoring Well Sampling Procedures

  • Maryland Groundwater Monitoring Well Sampling Procedures

  • Massachusetts Groundwater Monitoring Well Sampling Procedures

  • Michigan Groundwater Monitoring Well Sampling Procedures

  • Minnesota Groundwater Monitoring Well Sampling Procedures

  • Mississippi Groundwater Monitoring Well Sampling Procedures

  • Missouri Groundwater Monitoring Well Sampling Procedures

  • Montana Groundwater Monitoring Well Sampling Procedures

  • Nebraska Groundwater Monitoring Well Sampling Procedures

  • Nevada Groundwater Monitoring Well Sampling Procedures

  • New Hampshire Groundwater Monitoring Well Sampling Procedures

  • New Jersey Groundwater Monitoring Well Sampling Procedures

  • New Mexico Groundwater Monitoring Well Sampling Procedures

  • New York Groundwater Monitoring Well Sampling Procedures

  • North Carolina Groundwater Monitoring Well Sampling Procedures

  • North Dakota Groundwater Monitoring Well Sampling Procedures

  • Ohio Groundwater Monitoring Well Sampling Procedures

  • Oklahoma Groundwater Monitoring Well Sampling Procedures

  • Oregon Groundwater Monitoring Well Sampling Procedures

  • Pennsylvania Groundwater Monitoring Well Sampling Procedures

  • Rhode Island Groundwater Monitoring Well Sampling Procedures

  • South Carolina Groundwater Monitoring Well Sampling Procedures

  • South Dakota Groundwater Monitoring Well Sampling Procedures

  • Tennessee Groundwater Monitoring Well Sampling Procedures

  • Texas Groundwater Monitoring Well Sampling Procedures

  • Utah Groundwater Monitoring Well Sampling Procedures

  • Vermont Groundwater Monitoring Well Sampling Procedures

  • Virginia Groundwater Monitoring Well Sampling Procedures

  • Washington Groundwater Monitoring Well Sampling Procedures

  • West Virginia Groundwater Monitoring Well Sampling Procedures

  • Wisconsin Groundwater Monitoring Well Sampling Procedures

  • Wyoming Groundwater Monitoring Well Sampling Procedures

Copyright 2021 Proactive Environmental Products International LLC®. All rights Reserved.

Specifications change without notice

bottom of page