top of page

Item# P-10350

PROACTIVE ENVIRONMENTAL PRODUCTS®

12 Volt Mega-Typhoon® Plastic Pump

(Lifts 80 Feet / 24 Meters DTW)

12 Volt Mega-Typhoon Plastic Pump

The Engineered Plastic 12-volt submersible centrifugal Mega-Typhoon® pump is capable of pumping up to 80 feet from ground level (DTW)* by simply connecting the Mega-Typhoon® to a 12-volt deep cycle battery. Its reliable design is perfect for continuous sampling and purging of groundwater wells.

 

The 12 Volt Mega-Typhoon® can be used for low flow sampling (Fractional Flow®) all the way down to 40 mLs per minute. Need to get even lower?? How about 10 mLs per minute in conjunction with the Low Flow Sampling Control Valve.

 

Simplify and Expedite Your Next Sampling Event!

  • Mega-Typhoon® can operate under harsh conditions with higher turbidity.

 

  • Mega-Typhoon® can run continuously in water without the need for a cool down!

 

  • Mega-Typhoon® has a 400-hour motor life!

 

  • Mega-Typhoon® has a sleek outside that minimizes well hang-ups.

 

  • The Mega-Typhoon® is a very reliable and economical pump that provides a great bang for your buck!

 

This pump is not engineered to be dedicated in the physical liquid 24 hours a day.

​

*Depth to water

Specifications:

WATT CONSUMPTION (MAX):           270 WATTS (MAX)

DC VOLT RECOMMENDATION:          12-15 DC (direct current) At Source

AMP CONSUMPTION (MAX):            18 AMPS

MEASUREMENTS:                             LENGTH 12" / DIAMETER: 1.82"

REQUIRED TUBING:                          3/8" or 1/2" ID TUBING

SUPPLIED WITH:                               90 FEET OF HEAVY DUTY 12 GAUGE WIRE & YELLOW CONNECTOR

PUMP CONSTRUCTION:                     ABS

IMPELLER CONSTRUCTION:               POLY ACETAL (POM)

MOTOR SHAFT CONSTRUCTION:        STAINLESS STEEL 

WIRE CONSTRUCTION:                      PVC

SEAL CONSTRUCTION:                       NITRILE 

    Pumping Depth of Feet               Gallons Per Minute    

     DTW (Depth To Water)         At 13.8 Volts At The Source

 

                   10                                           3.5

 

                   20                                           3.1

 

                   40                                           2.0

 

                   50                                           1.5

 

                   70                                           .50

 

                   80                                           .25

 

                   85                                           N/A

 

Test was conducted with a Power Source at 13.8 volts using the
Low Flow with Power Booster 1 Controller  

 

Running your vehicle while using this pump with the Low Flow with Power Booster 1 Controller will dramatically increase purge volume

REQUIRES EITHER:

Retired

Dec 2018

(please note: one of the two boosters will be needed in order

for the technician to use the pump)

OPTIONAL:

ACCESSORIES:

State Groundwater Monitoring Well Sampling Procedures:

  • Alabama Groundwater Monitoring Well Sampling Procedures

  • Alaska Groundwater Monitoring Well Sampling Procedures

  • Arizona Groundwater Monitoring Well Sampling Procedures

  • Arkansas Groundwater Monitoring Well Sampling Procedures

  • California Groundwater Monitoring Well Sampling Procedures

  • Colorado Groundwater Monitoring Well Sampling Procedures

  • Connecticut Groundwater Monitoring Well Sampling Procedures

  • Delaware Groundwater Monitoring Well Sampling Procedures

  • Florida Groundwater Monitoring Well Sampling Procedures

  • Georgia Groundwater Monitoring Well Sampling Procedures

  • Hawaii Groundwater Monitoring Well Sampling Procedures

  • Idaho Groundwater Monitoring Well Sampling Procedures

  • Illinois Groundwater Monitoring Well Sampling Procedures

  • Indiana Groundwater Monitoring Well Sampling Procedures

  • Iowa Groundwater Monitoring Well Sampling Procedures

  • Kansas Groundwater Monitoring Well Sampling Procedures

  • Kentucky Groundwater Monitoring Well Sampling Procedures

  • Louisiana Groundwater Monitoring Well Sampling Procedures

  • Maine Groundwater Monitoring Well Sampling Procedures

  • Maryland Groundwater Monitoring Well Sampling Procedures

  • Massachusetts Groundwater Monitoring Well Sampling Procedures

  • Michigan Groundwater Monitoring Well Sampling Procedures

  • Minnesota Groundwater Monitoring Well Sampling Procedures

  • Mississippi Groundwater Monitoring Well Sampling Procedures

  • Missouri Groundwater Monitoring Well Sampling Procedures

  • Montana Groundwater Monitoring Well Sampling Procedures

  • Nebraska Groundwater Monitoring Well Sampling Procedures

  • Nevada Groundwater Monitoring Well Sampling Procedures

  • New Hampshire Groundwater Monitoring Well Sampling Procedures

  • New Jersey Groundwater Monitoring Well Sampling Procedures

  • New Mexico Groundwater Monitoring Well Sampling Procedures

  • New York Groundwater Monitoring Well Sampling Procedures

  • North Carolina Groundwater Monitoring Well Sampling Procedures

  • North Dakota Groundwater Monitoring Well Sampling Procedures

  • Ohio Groundwater Monitoring Well Sampling Procedures

  • Oklahoma Groundwater Monitoring Well Sampling Procedures

  • Oregon Groundwater Monitoring Well Sampling Procedures

  • Pennsylvania Groundwater Monitoring Well Sampling Procedures

  • Rhode Island Groundwater Monitoring Well Sampling Procedures

  • South Carolina Groundwater Monitoring Well Sampling Procedures

  • South Dakota Groundwater Monitoring Well Sampling Procedures

  • Tennessee Groundwater Monitoring Well Sampling Procedures

  • Texas Groundwater Monitoring Well Sampling Procedures

  • Utah Groundwater Monitoring Well Sampling Procedures

  • Vermont Groundwater Monitoring Well Sampling Procedures

  • Virginia Groundwater Monitoring Well Sampling Procedures

  • Washington Groundwater Monitoring Well Sampling Procedures

  • West Virginia Groundwater Monitoring Well Sampling Procedures

  • Wisconsin Groundwater Monitoring Well Sampling Procedures

  • Wyoming Groundwater Monitoring Well Sampling Procedures

Copyright 2021 Proactive Environmental Products International LLC®. All rights Reserved.

Specifications change without notice

bottom of page