12 Volt Abyss Slimline® Plastic Pump

(Lifts 220 Feet / 67 Meters DTW)

(For 4" schedule 80 well or larger)

12 Volt Abyss Slimline Plastic Pump

12 Volt Abyss Series

Pump Line Selecting Power & Autonomous Setup Video

12 Volt Abyss Series

Pump Line Video

The Engineered Plastic 12-volt Abyss Slimline® pump is capable of pumping up to 220 feet depth to water (DTW)* by simply connecting the Abyss Slimline® to a 12-volt deep cycle battery. Its reliable design and low amp consumption makes it the ideal pump for remediation pump and treat system. The Abyss Slimline® pump can run continuous, 24 hours a day, 7 days a week for remote situations when the pump needs to run when no technician is present. The Engineered Plastic Abyss Slimline® can even be used for low flow sampling (Fractional Flow®). Now you can sample all the way down to 40 mLs per minute with the Low Flow Sampling Controller. Need to get even lower?? How about 10 mLs per minute in conjunction with the Low Flow Sampling Control Valve.

 

Simplify and Expedite Your Next Sampling Event!

  • The Abyss Slimline® can operate under harsher conditions with higher turbidity. It can even run in oily, sandy liquid.

 

  • The Abyss Slimline® can run continuously 24 hours a day, 7 days a week. It can even run dry 24 hours a day, 7 days a week!! 

 

  • The Abyss Slimline® has a 3,000-hour motor life!

 

  • The Abyss Slimline® has a sleek outside that minimizes well hang-ups that easily fits into 4-inch wells or larger.

 

  • The Abyss Slimline® fits easily into a schedule 80, 4 inch well.

 

  • The Abyss Slimline® is widely used as a remediation pump for groundwater pump and treat situations.

 

  • The Abyss Slimline® is a very reliable and economical pump that provides a great bang for your buck!

 

The Abyss Slimline® is simple to make it a solar pump! Simply hook up your desired solar panel arrangement to the 80 Amp Solar Charger and then to a deep cycle marine battery(ies) for a turnkey solar pumping system that will last for years and years!

 

The Abyss Slimline® can also be hooked up to Proactive Environmental Products WeatherProof 110/220 Volt Step Down Transformer which can turn any high voltage situation into a safe low voltage pump.

 

The Abyss Slimline® can also run off the 50 amp gas powered 12 Volt Crusader®. This Gas driven Generator can produce 50 continuous amps of 12-volt power. No batteries are needed!

 

* Depth to water

Specifications:

 When Using Low Flow Sampling Controller, Pro Solar Charger #1, Pro Transformer #1, Pro Transformer #2, Pro Transformer #3 Or The Pro Controller #1

WATT CONSUMPTION (MAX):            60 WATTS (MAX)

DC VOLT RECOMMENDATION:           12-15 DC (direct current) At Source

AMP CONSUMPTION (MAX):             4 AMPS

MEASUREMENTS:                              LENGTH 12"/ DIAMETER: 3.73"

REQUIRED TUBING:                           3/8" ID or 1/2" ID TUBING

SUPPLIED WITH:                               230 FEET OF HEAVY DUTY 10 GAUGE WIRE, QUICK DISCONNECT

                                                        PLUG & BATTERY CLAMPS

SEAL AND VALVE CONSTRUCTION:     VITON (IS STANDARD UNLESS REQUESTED OTHERWISE) 

Specifications:

 When Using Abyss Solar Direct with LD and Float Switch

WATT CONSUMPTION (MAX):           75 WATTS (MAX)

DC VOLT RECOMMENDATION:           12-15 DC (direct current) At Source

AMP CONSUMPTION (MAX):             5 AMPS

MEASUREMENTS:                              LENGTH 12"/ DIAMETER: 3.73"

REQUIRED TUBING:                          3/8" ID or 1/2" ID TUBING

SUPPLIED WITH:                              230 FEET OF HEAVY DUTY 10 GAUGE WIRE, QUICK DISCONNECT

                                                       PLUG & BATTERY CLAMPS

SEAL AND VALVE CONSTRUCTION:    VITON (IS STANDARD UNLESS REQUESTED OTHERWISE) 

Specifications:

 When Using Abyss Transformer #4 Or Abyss Solar Charger #1

WATT CONSUMPTION (MAX):           75 WATTS (MAX)

DC VOLT RECOMMENDATION:           12-15 DC (direct current) At Source

AMP CONSUMPTION (MAX):             5 AMPS

MEASUREMENTS:                              LENGTH 12"/ DIAMETER: 3.73"

REQUIRED TUBING:                          3/8" ID or 1/2" ID TUBING

SUPPLIED WITH:                              230 FEET OF HEAVY DUTY 10 GAUGE WIRE, QUICK DISCONNECT

                                                       PLUG & BATTERY CLAMPS

SEAL AND VALVE CONSTRUCTION:    VITON (IS STANDARD UNLESS REQUESTED OTHERWISE) 

Specifications:

 When Using Abyss Booster #1 Or Abyss LD With Booster

WATT CONSUMPTION (MAX):          193.5 WATTS (MAX)

DC VOLT RECOMMENDATION:          12-15 DC (direct current) At Source

AMP CONSUMPTION (MAX):            12.9 AMPS

MEASUREMENTS:                             LENGTH 12"/ DIAMETER: 3.73"

REQUIRED TUBING:                          3/8" ID or 1/2" ID TUBING

SUPPLIED WITH:                               230 FEET OF HEAVY DUTY 10 GAUGE WIRE, QUICK DISCONNECT

                                                        PLUG & BATTERY CLAMPS

SEAL AND VALVE CONSTRUCTION:     VITON (IS STANDARD UNLESS REQUESTED OTHERWISE) 

When Used With: Low Flow Sampling Controller, Pro Solar Charger #1, Pro Transformer #1, Pro Transformer #2, Pro Transformer #3 Or Pro Controller #1      

     Pumping Depth in Feet                  Gallons Per Minute 
      DTW (Depth To Water)                 
                   10                                               1.15
         
                   20                                               1.0
          
                   40                                               1.0
          
                   60                                                .85
          
                   80                                                .85
         
                 100                                                .80
         
                 120                                                .80
         
                 140                                                .75
         
                 160                                                .75
         
                 180                                                .70
         
                 200                                                .70
         
                 220                                                .50
         
                 230                                         END OF WIRE
 
            Pump test was conducted with a Power Source at 13.8 volts.
 
                        Running your vehicle while using this pump
                            will dramatically increase purge volume

 When Used With: Abyss Solar Direct With LD and Float Switch  

 Pumping Depth in Feet              Gallons Per Minute With 

 DTW (Depth To Water)              Abyss Solar Direct Products                                                                                                 

               10                                               2.30

               20                                                 2.0

               40                                               1.75

               60                                               1.65

               80                                               1.65

             100                                               1.50

             120                                               1.50

             140                                               1.40

             160                                               1.40

             180                                               1.25

             200                                               1.25

             220                                                1.0

             230                                         END OF WIRE

 

 

Pump test was conducted on a cloudless sunny day using a single

245 watt Hanwha solar panel that produced 30 volts (VMP)

consistent with pump AMP draw of 8.64 per hour 

When Used With: Abyss Transformer #4 Or

Abyss Solar Charger #1

       Pumping Depth in Feet                Gallons Per Minute

       DTW (Depth To Water)             

                  

                    10                                               2.30

 

                    20                                               2.0

 

                    40                                               1.75

 

                    60                                               1.65

 

                    80                                               1.65

 

                  100                                               1.50

 

                  120                                               1.50

 

                  140                                               1.40

 

                  160                                               1.40

 

                  180                                               1.25

 

                  200                                               1.25

 

                  220                                               1.00

 

                  230                                         END OF WIRE

 

Pump test was conducted with Power Source at 13.8 volts.

 

When Used With: Abyss Booster #1 Or

Abyss LD With Booster

    Pumping Depth in Feet            Gallons Per Minute With

    DTW (Depth To Water)             Abyss Booster Products             

                  10                                              2.30

 

                  20                                                2.0

 

                  40                                              1.75

 

                  60                                              1.65

 

                  80                                              1.65

 

                100                                              1.50

 

                120                                              1.50

 

                140                                              1.40

 

                160                                              1.40

 

                180                                              1.25

 

                200                                              1.25

 

                220                                               1.0

 

                230                                        END OF WIRE

 

Pump test was conducted with a Power Source at 13.8 volts.

 

Running your vehicle while using this pump

will dramatically increase purge volume

 

State Groundwater Monitoring Well Sampling Procedures:

  • Alabama Groundwater Monitoring Well Sampling Procedures

  • Alaska Groundwater Monitoring Well Sampling Procedures

  • Arizona Groundwater Monitoring Well Sampling Procedures

  • Arkansas Groundwater Monitoring Well Sampling Procedures

  • California Groundwater Monitoring Well Sampling Procedures

  • Colorado Groundwater Monitoring Well Sampling Procedures

  • Connecticut Groundwater Monitoring Well Sampling Procedures

  • Delaware Groundwater Monitoring Well Sampling Procedures

  • Florida Groundwater Monitoring Well Sampling Procedures

  • Georgia Groundwater Monitoring Well Sampling Procedures

  • Hawaii Groundwater Monitoring Well Sampling Procedures

  • Idaho Groundwater Monitoring Well Sampling Procedures

  • Illinois Groundwater Monitoring Well Sampling Procedures

  • Indiana Groundwater Monitoring Well Sampling Procedures

  • Iowa Groundwater Monitoring Well Sampling Procedures

  • Kansas Groundwater Monitoring Well Sampling Procedures

  • Kentucky Groundwater Monitoring Well Sampling Procedures

  • Louisiana Groundwater Monitoring Well Sampling Procedures

  • Maine Groundwater Monitoring Well Sampling Procedures

  • Maryland Groundwater Monitoring Well Sampling Procedures

  • Massachusetts Groundwater Monitoring Well Sampling Procedures

  • Michigan Groundwater Monitoring Well Sampling Procedures

  • Minnesota Groundwater Monitoring Well Sampling Procedures

  • Mississippi Groundwater Monitoring Well Sampling Procedures

  • Missouri Groundwater Monitoring Well Sampling Procedures

  • Montana Groundwater Monitoring Well Sampling Procedures

  • Nebraska Groundwater Monitoring Well Sampling Procedures

  • Nevada Groundwater Monitoring Well Sampling Procedures

  • New Hampshire Groundwater Monitoring Well Sampling Procedures

  • New Jersey Groundwater Monitoring Well Sampling Procedures

  • New Mexico Groundwater Monitoring Well Sampling Procedures

  • New York Groundwater Monitoring Well Sampling Procedures

  • North Carolina Groundwater Monitoring Well Sampling Procedures

  • North Dakota Groundwater Monitoring Well Sampling Procedures

  • Ohio Groundwater Monitoring Well Sampling Procedures

  • Oklahoma Groundwater Monitoring Well Sampling Procedures

  • Oregon Groundwater Monitoring Well Sampling Procedures

  • Pennsylvania Groundwater Monitoring Well Sampling Procedures

  • Rhode Island Groundwater Monitoring Well Sampling Procedures

  • South Carolina Groundwater Monitoring Well Sampling Procedures

  • South Dakota Groundwater Monitoring Well Sampling Procedures

  • Tennessee Groundwater Monitoring Well Sampling Procedures

  • Texas Groundwater Monitoring Well Sampling Procedures

  • Utah Groundwater Monitoring Well Sampling Procedures

  • Vermont Groundwater Monitoring Well Sampling Procedures

  • Virginia Groundwater Monitoring Well Sampling Procedures

  • Washington Groundwater Monitoring Well Sampling Procedures

  • West Virginia Groundwater Monitoring Well Sampling Procedures

  • Wisconsin Groundwater Monitoring Well Sampling Procedures

  • Wyoming Groundwater Monitoring Well Sampling Procedures

Copyright 2021 Proactive Environmental Products International LLC®. All rights Reserved.

Specifications change without notice

bottom of page