top of page

Item# P-10380

PROACTIVE ENVIRONMENTAL PRODUCTS®

12 Volt Abyss® Plastic Pump

(Lifts 220 Feet / 67 Meters DTW)

(For 4" schedule 40 well or larger)

12 Volt Abyss Plastic Pump

12 Volt Abyss Series

Pump Line Video

12 Volt Abyss Series

Pump Line Selecting Power & Autonomous Setup Video

The Engineered Plastic 12-volt Abyss® pump is capable of pumping up to 220 feet depth to water (DTW)* by simply connecting the Abyss® to a 12-volt deep cycle battery. Its reliable design and low amp consumption makes it the ideal pump for remediation pump and treat system. The Abyss pump can run continuous, 24 hours a day, 7 days a week for remote situations when the pump needs to run when no technician is present. The Engineered Plastic Abyss® can even be used for low flow sampling (Fractional Flow®). Now you can sample all the way down to 40 mLs per minute with the Low Flow Sampling Controller. Need to get even lower?? How about 10 mLs per minute in conjunction with the Low Flow Sampling Control Valve.

 

Simplify and Expedite Your Next Sampling Event!

  • The Abyss® can operate under harsher conditions with higher turbidity. It can even run in oily, sandy liquid.

 

  • The Abyss can run continuously 24 hours a day, 7 days a week. It can even run dry 24 hours a day, 7 days a week!! 

 

  • The Abyss® has a 3,000-hour motor life!

 

  • The Abyss® has a sleek outside that minimizes well hang-ups that easily fits into 4-inch wells or larger.

 

  • The Abyss® is widely used as a remediation pump for groundwater pump and treat situations.

 

  • The Abyss® is a very reliable and economical pump that provides a great bang for your buck!

 

The Abyss® is simple to make it a solar pump! Simply hook up your desired solar panel arrangement to the 80 Amp Solar Charger and then to a deep cycle marine battery(ies) for a turnkey solar pumping system that will last for years and years!

 

The Abyss® can also be hooked up to Proactive Environmental Products Weatherproof 110/220 Volt Step Down Transformer which can turn any high voltage situation into a safe low voltage pump.

 

The Abyss® can also run off the 50 amp gas powered 12 Volt Crusader®. This Gas driven Generator can produce 50 continuous amps of 12-volt power. No batteries are needed!

 

* Depth to water

Specifications:

 When Using Low Flow Sampling Controller, Pro Solar Charger #1, Pro Transformer #1, Pro Transformer #2, Pro Transformer #3 Or The Pro Controller #1

WATT CONSUMPTION (MAX):           60 WATTS (MAX)

DC VOLT RECOMMENDATION:           12-15 DC (direct current) At Source

AMP CONSUMPTION (MAX):             4 AMPS

MEASUREMENTS:                              LENGTH 12"/ DIAMETER: 3.83"

REQUIRED TUBING:                          3/8" ID or 1/2" ID TUBING

SUPPLIED WITH:                               230 FEET OF HEAVY DUTY 10 GAUGE WIRE, QUICK 

                                                        DISCONNECT PLUG & BATTERY CLAMPS

SEAL AND VALVE CONSTRUCTION:     VITON (IS STANDARD UNLESS REQUESTED OTHERWISE) 

Specifications:

 When Using Abyss Solar Direct with LD and Float Switch

WATT CONSUMPTION (MAX):           75 WATTS (MAX)

DC VOLT RECOMMENDATION:           12-15 DC (direct current) At Source

AMP CONSUMPTION (MAX):             5 AMPS

MEASUREMENTS:                              LENGTH 12"/ DIAMETER: 3.83"

REQUIRED TUBING:                          3/8" ID or 1/2" ID TUBING

SUPPLIED WITH:                               230 FEET OF HEAVY DUTY 10 GAUGE WIRE, QUICK 

                                                        DISCONNECT PLUG & BATTERY CLAMPS

SEAL AND VALVE CONSTRUCTION:     VITON (IS STANDARD UNLESS REQUESTED OTHERWISE) 

Specifications:

 When Using Abyss Transformer #4 Or Abyss Solar Charger #1

WATT CONSUMPTION (MAX):           75 WATTS (MAX)

DC VOLT RECOMMENDATION:           12-15 DC (direct current) At Source

AMP CONSUMPTION (MAX):             5 AMPS

MEASUREMENTS:                              LENGTH 12"/ DIAMETER: 3.83"

REQUIRED TUBING:                          3/8" ID or 1/2" ID TUBING

SUPPLIED WITH:                               230 FEET OF HEAVY DUTY 10 GAUGE WIRE, QUICK 

                                                        DISCONNECT PLUG & BATTERY CLAMPS

SEAL AND VALVE CONSTRUCTION:     VITON (IS STANDARD UNLESS REQUESTED OTHERWISE) 

Specifications:

 When Using Abyss Booster #1 Or Abyss LD With Booster 

WATT CONSUMPTION (MAX):           193.5 WATTS (MAX)

DC VOLT RECOMMENDATION:           12-15 DC (direct current) At Source

AMP CONSUMPTION (MAX):             12.9 AMPS

MEASUREMENTS:                              LENGTH 12"/ DIAMETER: 3.83"

REQUIRED TUBING:                          3/8" ID or 1/2" ID TUBING

SUPPLIED WITH:                               230 FEET OF HEAVY DUTY 10 GAUGE WIRE, QUICK 

                                                        DISCONNECT PLUG & BATTERY CLAMPS

SEAL AND VALVE CONSTRUCTION:     VITON (IS STANDARD UNLESS REQUESTED OTHERWISE) 

 When Used With: Low Flow Sampling Controller, Pro Solar Charger #1, Pro Transformer #1, Pro Transformer #2, Pro Transformer #3 Or Pro Controller #1      

  Pumping Depth in Feet                   Gallons Per Minute      

  DTW (Depth To Water)            

 

              10                                                  1.15

         

              20                                                  1.0

          

              40                                                  1.0

          

              60                                                   .85

          

              80                                                   .85

         

            100                                                   .80

         

            120                                                   .80

         

            140                                                   .75

         

            160                                                   .75

         

            180                                                   .70

         

            200                                                   .70

         

            220                                                   .50

         

            230                                            END OF WIRE

 

Pump test was conducted with a Power Source at 13.8 volts.

 

Running your vehicle while using this pump

will dramatically increase purge volume

When Used With: Abyss Transformer #4 Or

Abyss Solar Charger #1

      Pumping Depth in Feet                Gallons Per Minute                  DTW (Depth To Water)                 

                 

                   10                                              2.30

                   20                                                2.0

                   40                                              1.75

                   60                                              1.65

                   80                                              1.65

                 100                                              1.50

                 120                                              1.50

                 140                                              1.40

                 160                                              1.40

                 180                                              1.25

                 200                                              1.25

                 220                                                1.0

  

                 230                                         END OF WIRE

 

 

 

Pump test was conducted with a Power Source at 13.8 volts

When Used With: Abyss Solar Direct With LD and Float Switch

   Pumping Depth in Feet                Gallons Per Minute With

   DTW (Depth To Water)               Abyss Solar Direct Products

                                                                    

                10                                                  2.30

                20                                                    2.0

                40                                                  1.75

                60                                                  1.65

                80                                                  1.65

              100                                                  1.50

              120                                                  1.50

              140                                                  1.40

              160                                                  1.40

              180                                                  1.25

              200                                                  1.25

              220                                                   1.0

              230                                            END OF WIRE


 

Pump test was conducted on a cloudless sunny day using a single 245

watt Hanwha solar panel that produced 30 volts (VMP)

consistent with pump AMP draw of 8.64 per hour

 

When Used With: Abyss Booster #1 Or

Abyss LD With Booster

 Pumping Depth in Feet               Gallons Per Minute With  DTW (Depth To Water)                 Abyss Booster Products              

               10                                                 2.30

               20                                                   2.0

               40                                                 1.75

               60                                                 1.65

               80                                                 1.65

             100                                                 1.50

             120                                                 1.50

             140                                                 1.40

             160                                                 1.40

             180                                                 1.25

             200                                                 1.25

             220                                                  1.0

             230                                           END OF WIRE

Pump test was conducted with a Power Source at 13.8 volts.

Running your vehicle while using this pump

will dramatically increase purge volume

 

State Groundwater Monitoring Well Sampling Procedures:

  • Alabama Groundwater Monitoring Well Sampling Procedures

  • Alaska Groundwater Monitoring Well Sampling Procedures

  • Arizona Groundwater Monitoring Well Sampling Procedures

  • Arkansas Groundwater Monitoring Well Sampling Procedures

  • California Groundwater Monitoring Well Sampling Procedures

  • Colorado Groundwater Monitoring Well Sampling Procedures

  • Connecticut Groundwater Monitoring Well Sampling Procedures

  • Delaware Groundwater Monitoring Well Sampling Procedures

  • Florida Groundwater Monitoring Well Sampling Procedures

  • Georgia Groundwater Monitoring Well Sampling Procedures

  • Hawaii Groundwater Monitoring Well Sampling Procedures

  • Idaho Groundwater Monitoring Well Sampling Procedures

  • Illinois Groundwater Monitoring Well Sampling Procedures

  • Indiana Groundwater Monitoring Well Sampling Procedures

  • Iowa Groundwater Monitoring Well Sampling Procedures

  • Kansas Groundwater Monitoring Well Sampling Procedures

  • Kentucky Groundwater Monitoring Well Sampling Procedures

  • Louisiana Groundwater Monitoring Well Sampling Procedures

  • Maine Groundwater Monitoring Well Sampling Procedures

  • Maryland Groundwater Monitoring Well Sampling Procedures

  • Massachusetts Groundwater Monitoring Well Sampling Procedures

  • Michigan Groundwater Monitoring Well Sampling Procedures

  • Minnesota Groundwater Monitoring Well Sampling Procedures

  • Mississippi Groundwater Monitoring Well Sampling Procedures

  • Missouri Groundwater Monitoring Well Sampling Procedures

  • Montana Groundwater Monitoring Well Sampling Procedures

  • Nebraska Groundwater Monitoring Well Sampling Procedures

  • Nevada Groundwater Monitoring Well Sampling Procedures

  • New Hampshire Groundwater Monitoring Well Sampling Procedures

  • New Jersey Groundwater Monitoring Well Sampling Procedures

  • New Mexico Groundwater Monitoring Well Sampling Procedures

  • New York Groundwater Monitoring Well Sampling Procedures

  • North Carolina Groundwater Monitoring Well Sampling Procedures

  • North Dakota Groundwater Monitoring Well Sampling Procedures

  • Ohio Groundwater Monitoring Well Sampling Procedures

  • Oklahoma Groundwater Monitoring Well Sampling Procedures

  • Oregon Groundwater Monitoring Well Sampling Procedures

  • Pennsylvania Groundwater Monitoring Well Sampling Procedures

  • Rhode Island Groundwater Monitoring Well Sampling Procedures

  • South Carolina Groundwater Monitoring Well Sampling Procedures

  • South Dakota Groundwater Monitoring Well Sampling Procedures

  • Tennessee Groundwater Monitoring Well Sampling Procedures

  • Texas Groundwater Monitoring Well Sampling Procedures

  • Utah Groundwater Monitoring Well Sampling Procedures

  • Vermont Groundwater Monitoring Well Sampling Procedures

  • Virginia Groundwater Monitoring Well Sampling Procedures

  • Washington Groundwater Monitoring Well Sampling Procedures

  • West Virginia Groundwater Monitoring Well Sampling Procedures

  • Wisconsin Groundwater Monitoring Well Sampling Procedures

  • Wyoming Groundwater Monitoring Well Sampling Procedures

Copyright 2021 Proactive Environmental Products International LLC®. All rights Reserved.

Specifications change without notice